Difference between revisions of "Issues SC2008"

From NavykI
Jump to: navigation, search
(Structure)
(Administrator)
Line 5: Line 5:
  
 
== Administrator ==
 
== Administrator ==
*How to create project without password?
 
** NOTE- It is not about the project, it's only a user setting.
 
** ''Open '''Administrator''' → Login to server '''NAVYK-SERVER\SHIPCON''' using password '''"ShipCon"''' →  '''Tools''' menu → '''Manage users''' → Select the user for whom you want to change the password → '''Change password'''''
 
  
 
== Manager ==
 
== Manager ==

Revision as of 08:37, 11 September 2009

General

  • How to display the SC ribbons?
    • Local problem? Knowledge base does not mention it. Requires further investigation.

Administrator

Manager

  • Correct settings for text style, height, etc. (they disappear after exploding nests?! DXF?!)

Hull

  • minimum import tolerance is 0.1mm, how to increase?
    • 0.1 is the minimum value for SC.
  • trim lines in hull gives big differences because of NURBS lines are transformed into polylines
    • Trim the surfaces with Rhino imported curves (exploded), not with nurbs.

Structure

  • layer management (important for bound approval)
    • The AutoCad setting LAYEREVALCTL must be 0. Disables the evaluation and notification of new layers.
    • For more details search Acad Help for "Use New Layer Notification"
  • Unreconciled layers cannot be plotted in AutoCad2006.
    • Workaround: open and save the drawing in Rhino.
  • Export - exports all layers, how to export only the solid layers?

Nest

  • Paint is not correct updated in the BOM
    • Solved
  • Nest template - text style
    • Solved
  • Nest - layer use
    • all on STOCK now
  • Parts cannot be exploded outside the project (for export to NC-Pyros)
    • Workaround: Export each nest as DXF