Difference between revisions of "Tanks"
From NavykI
(New page: == Types of tanks == * Fuel * Fresh water * Waste water: ** Grey water ** Black water * Dirty oil * Return oil * Lube oil == Tank considerations == * Tanks are being considered as full...) |
|||
Line 11: | Line 11: | ||
− | == | + | == General considerations == |
* Tanks are being considered as full when filled at 98% to allow room for expansion | * Tanks are being considered as full when filled at 98% to allow room for expansion | ||
+ | * Low level alarm is at around 10%, high level at 95% and high high level at 98% | ||
+ | * Fuel and fresh water tanks require a breather line with the same diameter as the fill line to avoid spilling when filling with pressure. | ||
+ | |||
+ | == Fuel tanks == | ||
+ | |||
* Fuel tanks require paint inside to avoid corrosion (only for full tanks corrosion is not an issue but this is only applicable for boats in 24h service) | * Fuel tanks require paint inside to avoid corrosion (only for full tanks corrosion is not an issue but this is only applicable for boats in 24h service) | ||
− | * | + | |
+ | |||
+ | == Waste water tanks == | ||
+ | |||
+ | * Waste water tanks require a breather line with the same diameter as the suction line to avoid collapsing during emptying. Instead of a large diameter breather line a valve can be applied. | ||
+ | * Deck suction connection conform ISO... | ||
Revision as of 17:28, 26 March 2010
Contents
[hide]Types of tanks
- Fuel
- Fresh water
- Waste water:
- Grey water
- Black water
- Dirty oil
- Return oil
- Lube oil
General considerations
- Tanks are being considered as full when filled at 98% to allow room for expansion
- Low level alarm is at around 10%, high level at 95% and high high level at 98%
- Fuel and fresh water tanks require a breather line with the same diameter as the fill line to avoid spilling when filling with pressure.
Fuel tanks
- Fuel tanks require paint inside to avoid corrosion (only for full tanks corrosion is not an issue but this is only applicable for boats in 24h service)
Waste water tanks
- Waste water tanks require a breather line with the same diameter as the suction line to avoid collapsing during emptying. Instead of a large diameter breather line a valve can be applied.
- Deck suction connection conform ISO...