Difference between revisions of "Alarm system"

From NavykI
Jump to: navigation, search
 
(2 intermediate revisions by the same user not shown)
Line 9: Line 9:
  
 
*DVR surveylence
 
*DVR surveylence
**use meye for mobile phones
+
**use ViewCam Lite for mobile phones
 
**IP: 5.2.208.29 (for mobile devices)5.2.208.29 new use [navyk.com] on mobile phones
 
**IP: 5.2.208.29 (for mobile devices)5.2.208.29 new use [navyk.com] on mobile phones
 
**IP: 192.168.11.9:85 or http://cameras.navyk.local/ (internet explorer from inside the office)
 
**IP: 192.168.11.9:85 or http://cameras.navyk.local/ (internet explorer from inside the office)
Line 27: Line 27:
 
**If we press and keep pressed the triangle button (medical emergency) the alarm will start calling the notification numbers(no alarm from the outside unit)
 
**If we press and keep pressed the triangle button (medical emergency) the alarm will start calling the notification numbers(no alarm from the outside unit)
  
*When the alarm starts it will start calling Steven, Marlena and Ovidiu.
+
*When the alarm starts it will start calling Simona, Bogdan and Ovidiu. (not necessarily in this order)
 
**To let the alarm to call the next number you can dismiss the call.
 
**To let the alarm to call the next number you can dismiss the call.
 
**To stop the alarm you need to answer the phone and longpress the 1 key from the phone.
 
**To stop the alarm you need to answer the phone and longpress the 1 key from the phone.

Latest revision as of 09:37, 7 April 2017

Bogdan is in charge

Navyk alarm system consists of:

  • Central alarm:
    • smoke sensors
    • movement sensors
    • door contact
  • DVR surveylence
    • use ViewCam Lite for mobile phones
    • IP: 5.2.208.29 (for mobile devices)5.2.208.29 new use [navyk.com] on mobile phones
    • IP: 192.168.11.9:85 or http://cameras.navyk.local/ (internet explorer from inside the office)
    • port: 85
    • user: navyk
  • Alarm visualization
    • *3 will show the alarmcode
      • 1-movement sensor entrance
      • 2-6 movement sensors (2 is East window, 6 is West window)
      • 7 entrance switch
      • 8 free
      • 9 smoke sensor entrance (old part of the office)
      • 10 smoke sensor Cristi (new part of the office)
      • 11 smoke sensor Steven (corner partition)
      • 12 smoke sensor server room
    • If we press and keep pressed the triangle button (medical emergency) the alarm will start calling the notification numbers(no alarm from the outside unit)
  • When the alarm starts it will start calling Simona, Bogdan and Ovidiu. (not necessarily in this order)
    • To let the alarm to call the next number you can dismiss the call.
    • To stop the alarm you need to answer the phone and longpress the 1 key from the phone.
      • Sometimes it might skip the next number if you dismiss the call
    • When we press 1 it will stop the phone loop, but the alarm will continue ringing until there is no stimulation to the sensors.
  • If we want Gabi can provide a wire to Arduino in order to start the alarm with the existing smoke sensors(4 signal wires can be provided).


Section added by Bogdan[edit]

  • Reset fire alarm: *72
  • Display last alarm: *3
  • Return: #