Difference between revisions of "12024 Fish boat 700"
From NavykI
(→60 Systems) |
(→60 Systems) |
||
Line 51: | Line 51: | ||
***''It is the responsibility of the owner/operator to have at least one bailer/draw bucket on board, secured against accidental loss.'' | ***''It is the responsibility of the owner/operator to have at least one bailer/draw bucket on board, secured against accidental loss.'' | ||
***''ISO recommends the use of a bilge pump(recommends only and does not mention the type)'' | ***''ISO recommends the use of a bilge pump(recommends only and does not mention the type)'' | ||
− | ***''capacity - 15 l/min for boats with LH greater than 6 m and less than 12 m | + | ***''capacity - 15 l/min for boats with LH greater than 6 m and less than 12 m'' |
***''no secondary bilge pump is required'' | ***''no secondary bilge pump is required'' | ||
*Steering - hydraulic lines through keel stainless steel pipe | *Steering - hydraulic lines through keel stainless steel pipe |
Revision as of 12:59, 4 September 2012
Contents
General
Description
Contacts
Classification
- CE category D
- bilge system - electrical only is allowed?
- fire protection - extinguisher
- fire protection - extinguisher port in engine box
- fuel system - shut down by means of ball valve operated by T-handle in dashboard (Exalto)
- steering system - emergency tiller
Scope
- CE technical file €1000
- English language only
- excluding owner's manual
Drawing list
Time schedule
Questions
To do
10 General
- LOA 700
- BOA 240 (for trailering)
- inboard diesel (20hp?)
40 Construction
- keel - fill completely with a compound?
- steel 5mm (no filler), bottom 8mm?
- no frames/floors
50 Outfitting
- rope fender around boat
60 Systems
- Exhaust
- exhaust - requires air vent (Vetus: minimum 400m above waterline)
- exhaust - from engine box to transom stainless steel pipe
- Bilge - from engine box to transom stainless steel pipe
- ISO requirements for open deck or partially sheltered cat D:
- It is the responsibility of the owner/operator to have at least one bailer/draw bucket on board, secured against accidental loss.
- ISO recommends the use of a bilge pump(recommends only and does not mention the type)
- capacity - 15 l/min for boats with LH greater than 6 m and less than 12 m
- no secondary bilge pump is required
- ISO requirements for open deck or partially sheltered cat D:
- Steering - hydraulic lines through keel stainless steel pipe
- Fuel
- fuel tank - PP custom made
- fuel fill - filler cap directly on top of tank
- fuel tank vent - hole in filler cap
- Fuel tank is allowed in the engine compartment?For Alex to check
70 Interior
80 Paint
- epoxy tar - hull and interior
- deck - other colour