*CE category D | *CE category D | ||
*bilge system - electrical only is allowed? | *bilge system - electrical only is allowed? | ||
− | *fire protection - extinguisher | + | *fire protection - extinguisher(fire extinguisher shall be located within 1 m from the main helm position or the cockpit for boats with LH < 10 m) |
*fire protection - extinguisher port in engine box | *fire protection - extinguisher port in engine box | ||
*fuel system - shut down by means of ball valve operated by T-handle in dashboard (Exalto) | *fuel system - shut down by means of ball valve operated by T-handle in dashboard (Exalto) |
Revision as of 15:44, 4 September 2012
Contents
General
Description
Contacts
Classification
- CE category D
- bilge system - electrical only is allowed?
- fire protection - extinguisher(fire extinguisher shall be located within 1 m from the main helm position or the cockpit for boats with LH < 10 m)
- fire protection - extinguisher port in engine box
- fuel system - shut down by means of ball valve operated by T-handle in dashboard (Exalto)
- steering system - emergency tiller
Scope
- CE technical file €1000
- English language only
- excluding owner's manual
Drawing list
Time schedule
Questions
To do
10 General
- LOA 700
- BOA 240 (for trailering)
- inboard diesel (20hp?)
40 Construction
- keel - fill completely with a compound?
- steel 5mm (no filler), bottom 8mm?
- no frames/floors
50 Outfitting
- rope fender around boat
60 Systems
- Exhaust
- exhaust - requires air vent (Vetus: minimum 400m above waterline)
- exhaust - from engine box to transom stainless steel pipe
- Bilge - from engine box to transom stainless steel pipe
- ISO requirements for open deck or partially sheltered cat D:
- It is the responsibility of the owner/operator to have at least one bailer/draw bucket on board, secured against accidental loss.
- ISO recommends the use of a bilge pump(recommends only and does not mention the type)
- capacity - 15 l/min for boats with LH greater than 6 m and less than 12 m
- these volumes shall be achieved when the pump is subjected to a pressure of 10 kPa. For manual bilge pumps, the capacity shall be rated for 45 strokes per minute
- no secondary bilge pump is required
- ISO requirements for open deck or partially sheltered cat D:
- Steering - hydraulic lines through keel stainless steel pipe
- Fuel
- fuel tank - PP custom made
- fuel fill - filler cap directly on top of tank
- fuel tank vent - hole in filler cap
- fuel tank is allowed in the engine compartment
- an air gap to prevent any contact between the tank and engine is required(unless an equivalent thermal barrier is provided) (ISO 9094-1)
- 100 mm between a petrol engine and a fuel tank
- 250 mm between a dry exhaust and a fuel tank
70 Interior
80 Paint
- epoxy tar - hull and interior
- deck - other colour